Technical Information:
The GK & UK sliding ramps operate spring return type limit switches. The roller at the roller lever is brought by the inclined contact surface into the corresponding switching position. If the sliding ramp is removed, the switch will return to its original position. Operating ramps are used for direction limit switches. If the roller of the roller lever leaves the operating cam, the stay-put feature of the direction limit switch ensures that it remains in the last switching position.
The long versions of both types of ramps are designed for high speed elevators, the short versions are designed for slow speed elevators.